Distribution boards and electrical equipment

Uninsulated neutral terminal 1x25mm² + 8x16mm² L=73mm Legrand, LEGRAND LOW VOLTAGE, 4803
Uninsulated neutral terminal 1x25mm² + 8x16mm² L=73mm Legrand, LEGRAND LOW VOLTAGE, 4803
€2,77 €3,38
Terminal block YELLOW/GRAY 95 mm² SCREWLESS with grounding connection to the base, TOPJOB® S series, Wago, WAGO, 285-191
Terminal block YELLOW/GREY 95mm2 SCREWLESS with earth connection to the base TOPJOB® S series Wago, WAGO, 285-191

€33,49

Contactor AF16Z-40-00 4P 7.5kW (18A AC-3) 24V DC ABB, 1SBL176201R3000
ABB
Contactor, 4P, 7,5 kW at 400 V AC-3, 24 V DC coil ABB 1SBL176201R3000
€64,11 €78,18
D2 12A 2P I-0 switch-disconnector in enclosure 110x150x87mm IP66 Isolators PV1 1000V= Scame, SCAME, 590.DCGE11012
Cam switch D2 12A 2P I-0 in enclosure 110x150x87mm IP66 Isolators PV1 1000V= Scame, SCAME, 590.DCGE11012
€85,11 €103,79
DMX³ air circuit breaker 2500A 3P 65kA Legrand 028386, LEGRAND LOW VOLTAGE, V/NDMX3VF/2500A
Air circuit breaker DMX³ 2500А 3P 65 kA Legrand 028386, LEGRAND LOW VOLTAGE, V/NDMX3VF/2500A
€5.917,01 €7.215,86
AF580-30-11 contactor 3P 315kW (580A AC-3) 1NO+1NC 250...500V 50/60Hz ABB, 1SFL617001R7111
ABB
Contactor AF580-30-11 3P 315kW (580A AC-3) 1NO+1NC 250...500V 50/60Hz ABB, 1SFL617001R7111
€1.581,24 €1.928,34
Mounting clip for DIN rail FIX-KLIPM4 M4 screw MOREK, MMD5104A23
Mounting clip for DIN rail FIX-KLIPM4 screw M4 MOREK, MMD5104A23

€1,09

Contactor B7-40-00 4P 5.5kW (16A AC-3) 230V 50/60Hz ABB, GJL1311201R8000
ABB
Contactor B7-40-00 4P 5.5kW (16A AC-3) 230V 50/60Hz ABB, GJL1311201R8000
€24,60 €30,00
RCD 2P 100A 300mA TX3 series ID type AC Legrand, LEGRAND LOW VOLTAGE, 411533
RCD 2P 100A 300 mA series TX3 ID type AC Legrand, LEGRAND LOW VOLTAGE, 411533
€71,42 €87,10
Contactor AF146-30-22 3P 75kW (146A AC-3) 2NO+2NC 24...60V 50/60Hz ABB, 1SFL467001R1122
ABB
Contactor AF146-30-22 3P 75kW (146A AC-3) 2NO+2NC 24...60V 50/60Hz ABB, 1SFL467001R1122
€381,27 €464,96
H400 solid mounting plate W800 QM0804000 SpEe ABB, 1SZE980070B0170
ABB
Mounting plate COMBI 400 × 800 mm ABB 1SZE980070B0170
€57,43 €70,04
Flush-mounted distribution board, 3x18 modules, SecoraLine, with transparent door and N and PE terminals ABB, 4TBD640066C0100
ABB
Flush-mounted distribution board 3х18 mod. SecoraLine with transparent door and Н and РЕ terminals ABB, 4TBD640066C0100
€77,33 €94,30
Label holder 8x27mm with SE, SCHNEIDER ELECTRIC LOW VOLTAGE label, ZBY2101
Label holder 8х27 mm with plate SE, SCHNEIDER ELECTRIC LOW VOLTAGE, ZBY2101
€1,85 €2,26
Diode 42 6...24 V DC for CR-P/M ABB interface relay, 1SVR405652R1000
ABB
Diode 42 6...24 V DC for interface relay CR-P/M ABB, 1SVR405652R1000
€2,36 €2,88
Acti 9 iC60N 1P+N 10A curve C 6kA SE circuit breaker, SCHNEIDER ELECTRIC LOW VOLTAGE, A9F74610
Circuit breaker Acti 9 iC60N 1P+N 10A curve C 6kA SE, SCHNEIDER ELECTRIC LOW VOLTAGE, A9F74610
€17,27 €21,06
Cam switch 0-1 4P 40A with enclosure IP65, red handle, Legrand, LEGRAND LOW VOLTAGE, 22184
Cam switch 0-1 4P 40A with IP65 enclosure, red handle, Legrand, LEGRAND LOW VOLTAGE, 22184
€164,16 €200,20
NSX100F 3P circuit breaker without protection 36kA SE, SCHNEIDER ELECTRIC LOW VOLTAGE, C10F3
Base for ComPacT NSX100F circuit breaker, 3P, 100 A Schneider Electric C10F3
€235,45 €287,14
Metal enclosure 1200×600×250 Q843B600 SpEe L IP43 ABB, 1SZE430800B0120
ABB
Metal enclosure 1200×600×250 Q843B600 SpEe L IP43 ABB, 1SZE430800B0120
€198,51 €242,08
Surface-mounted panel, 1x8 modules, IKONA series, IP66 IK09, Scame - 679.1008
Surface-mounted enclosure 1х8 mod., series IKONA IP66 IK09 Scame - 679.1008
€21,43 €26,13
SCHNEIDER ELECTRIC - Acti 9 iCT modular contactor 63A 4NC 230…240Vac 3 mod. A020060036
SCHNEIDER ELECTRIC - Modular contactor Acti 9 iCT 63A 4NC 230…240Vac 3 modules A020060036
€73,46 €89,59
T Max XT3N 250A TM 4P 36kA InN=50% adjustable (In x 0.7...1) ABB, ABB, 1SDA068066R1
ABB
T Max circuit breaker XT3N 250A TM 4P 36kA InN=50% adjustable (In x 0.7...1) АВВ, ABB, 1SDA068066R1
€407,79 €497,30
Explosion-proof EX enclosure 230x75x75mm IP66, with 8x M20 plugs, 20xWDU 2.5mm², Zenith-P EX series Scame, SCAME, 644.0240-J20
Explosion-proof box EX 230x75x75mm IP66, with 8х plugs М20, 20xWDU 2,5mm², Zenith-P series ЕX Scame, SCAME, 644.0240-J20
€168,07 €204,96
H350 solid front panel W600 QCC063501 SpEe ABB, 1SZE980010B0175
ABB
Front panel H350 solid W600 QCC063501 SpEe ABB, 1SZE980010B0175
€24,62 €30,02
TeSys G contactor 3P 375 kW (630 A AC-3) 1NO-1NC 100...250 V 50/60Hz SE, SCHNEIDER ELECTRIC LOW VOLTAGE, LC1G630KUEN
TeSys G contactor 3P 375kW (630A AC-3) 1NO-1NC 100...250V 50/60Hz SE, SCHNEIDER ELECTRIC LOW VOLTAGE, LC1G630KUEN
€2.164,23 €2.639,30
DMX-SP air circuit breaker 4000A 3P 65kA Legrand 670266, LEGRAND LOW VOLTAGE, V/NDMX3VF/4000A
Air circuit breaker DMX-SP 4000 A 3P 65 kA Legrand 670266, LEGRAND LOW VOLTAGE, V/NDMX3VF/4000A
€7.031,76 €8.575,32
MA1-8015 tool for securing Ø22mm heads ABB, 1SFA611920R8015
ABB
MA1-8015 mounting tool for CombiLine-Compact ABB 1SFA611920R8015
€3,49 €4,26
NSXm B 3P 100A TM 25kA circuit breaker, for DIN rail mounting, adjustable (In x 0.7...1) SE, SCHNEIDER ELECTRIC LOW VOLTAGE, C11B3TM100L
NSXm B circuit breaker 3P 100A TM 25kA, for DIN mounting, adjustable (In x 0.7...1) SE, SCHNEIDER ELECTRIC LOW VOLTAGE, C11B3TM100L
€245,16 €298,98
Flexible insulated copper busbar Moflex MMC 32x1x3 96mm² 2m 1000V MOREK, MMC0320301
Flexible insulated copper busbar Moflex MMC 32x1x3 96mm² 2m 1000V MOREK, MMC0320301

€119,89

Flexible insulated copper busbar Moflex MMC 24x1x8 192mm² 2m 1000V MOREK, MMC0240801
Flexible insulated copper busbar Moflex MMC 24x1x8 192mm² 2m 1000V MOREK, MMC0240801

€221,89

NSX630DC PV circuit breaker 4P 500A 10kA 1000V= adjustable (In x 0.7...1) SE, SCHNEIDER ELECTRIC LOW VOLTAGE, C63F4TM500D1
Circuit breaker NSX630DC PV 4P 500A 10kA 1000V= adjustable (In x 0.7...1) SE, SCHNEIDER ELECTRIC LOW VOLTAGE, C63F4TM500D1
€1.112,95 €1.357,26

Popular

VGTECH

More from VGTECH

Latrans

More from Latrans

COMMEL

More from COMMEL

ORNO

More from ORNO

BTICINO

More from BTICINO

LEGRAND

More from LEGRAND

Recently viewed

Distribution boards and electrical equipment brings together enclosures, protective devices, controls and assembly components. Start with each part's task to compare the products required in the appropriate area.

Choose the enclosure and its contents separately

In electrical distribution boards , distinguish distribution enclosures from industrial and socket configurations. Check mounting, space and included contents. The box itself does not mean a complete wired distribution board. For mounting elements, terminals, busbar combs and supplementary enclosure parts, continue to distribution board assembly. Keep the enclosure, mechanical base and conductor connections as different items.

Distinguish protection areas

In circuit breakers and fuses , first choose between an automatic device, fuse link and load-break or disconnecting version. Then compare the exact series and parameters required. For other protection tasks, use residual current devices and surge protection. The general label “protection” does not make different equipment types equivalent substitutes.

In every area, separate the main device from spare parts and accessories. An interchangeable module, holder or additional contact should not be assumed to be a complete set. Keep the product's full designation and check its exact configuration, especially when some existing equipment remains in use.

Control, timed tasks and operator elements

Continue to motor control and protection for contactor, motor protection, thermal overload and variable frequency areas. For individual relay functions, explore relays and timers. Compare function, power supply version, outputs and mounting space by the specific reference. Control section data should not be confused with the parameters of the remaining equipment.

For the control panel, use push buttons, indicators and switches. Separate the assembled device from its head, contact and mounting elements. An empty control station and a complete offer are different purchases. Colour or similar shape alone does not determine package contents or compatibility between parts from different series. Note separately supplied markings and mounting parts.

For the final list, record every component's purpose, exact code, required accessories and included parts. For enclosures, check their own use conditions; for devices, compatibility with the specific equipment. This organises the actual solution by function without deriving general electrical characteristics or compatibility from membership of one category.