HAGER

I-0-II switch, DIN rail mount, SFT240, 40A, 2P, 230V, 2 modules, Hager, HAGER
Changeover switch I-0-II DIN mounting SFT240 40A 2P 230V 2 mod. Hager, HAGER

€28,21

Switch I-0-II DIN mount SFT440 40A 4P 400V 4 modules Hager, HAGER
Changeover switch I-0-II DIN mounting SFT440 40A 4P 400V 4 mod. Hager, HAGER

€67,07

Changeover switch I-0-II, DIN rail mounting, SFT340, 40A, 3P, 400V, 3 modules, Hager, HAGER
Changeover switch I-0-II DIN mounting SFT340 40A 3P 400V 3 mod. Hager, HAGER

€46,67

Cam switch I-0-II DIN rail mounting SF263 63A 2P 250V 4 mod. Hager, HAGER
Changeover switch I-0-II DIN mounting SF263 63A 2P 250V 4 mod. Hager, HAGER

€85,28

Load break switch I-0-II, DIN rail mounting, SFT140, 40A, 1P, 230V, 1 module, Hager, HAGER
Changeover switch I-0-II DIN rail mounting SFT140 40A 1P 230V 1 module Hager, HAGER

€20,40

Changeover switch I-0-II, DIN rail mounting, SF463, 63A, 4P, 400V, 8 modules, Hager, HAGER
Changeover switch I-0-II DIN mounting SF463 63A 4P 400V 8 mod. Hager, HAGER

€205,39

Popular

VGTECH

Shop all VGTECH

Latrans

Shop all Latrans

COMMEL

Shop all COMMEL

ORNO

Shop all ORNO

BTICINO

Shop all BTICINO

LEGRAND

Shop all LEGRAND

Recently viewed

HAGER at Latrand focuses on SFT and SF manual modular switches. In this range, the main distinctions are the number of poles, switching positions and exact operating parameters. The designation I-0-II describes a switching function without in itself meaning automatic control or protective tripping.

Single-pole and three-pole versions

SFT140 is a single-pole modular changeover switch with a centre-off position. A rated current of 40 A, operating voltage of 230 V AC and width of one module are stated for it. It is intended for a DIN rail and has IP20. These characteristics describe the specific SFT140; they are not transferred to all models whose names begin with SFT or SF.

SFT340 is a three-pole I-0-II. switch. This model specifies 40 A, 400 V AC and a width of three modules. An identical current designation therefore does not mean the same pole count, operating voltage or distribution board space. Record these parameters separately to avoid choosing a visually similar but differently configured device.

Utilisation category is part of the parameter

In the SFT340 datasheet, the value 40 A is stated for categories AC21 and AC22. It must not be treated as an unrestricted current for any motor or other inductive load. Operating voltage is also considered separately from insulation voltage: different values in technical data may have different purposes, rather than being interchangeable descriptions of one condition.

Switching and protection serve different purposes

In load-break switches and disconnectors , explore the context of this equipment. A manual switching function does not prove automatic transfer between sources or overload protection. If the design requires such functions, specify them separately; do not add them to the designation I-0-II. by assumption.

For general selection, continue to circuit breakers and fuses. Prepare the exact switch code, number of poles, position required and operating conditions as independent criteria. The series also includes other SFT and SF designations, but choosing between them requires the corresponding model data. This prevents a parameter of SFT140 or SFT340 from being incorrectly used for another variant solely because of a shared family name.