Distribution boards and electrical equipment

Soft starter 3P 5.5kW ATS01 12A 380...415V IP20 SE, SCHNEIDER ELECTRIC LOW VOLTAGE, ATS01N212QN
Soft starter 3P 5.5kW ATS01 12A 380...415V IP20 SE, SCHNEIDER ELECTRIC LOW VOLTAGE, ATS01N212QN
€270,70 €330,12
Multifunction time relay, 16x 0.01s…100h, LCD, 2c/o 16A, 12...240Vac/dc, 3DIN, Elko EP, ELKO EP, PDR-2A/UNI
Multifunction time relay, 16x 0.01s…100h, LCD, 2c/o 16A, 12...240Vac/dc, 3DIN, Elko EP, ELKO EP, PDR-2A/UNI

€97,93

GRAY tunnel terminal 1P 425A with 4 holes OTL240-2 2xAl/Cu 35-240mm² 1000V MOREK, MAA2240A10
Tunnel terminal GREY 1P 425A with openings: 4 OTL240-2 2xAl/Cu 35-240mm² 1000V MOREK, MAA2240A10

€41,63

Distribution terminal block СИВ 1P 400A OJL400A input Al/Cu 1x 240 output 4x35/3x50mm² MOREK, MAB1401S10
Distribution terminal block GREY 1P 400A OJL400A input Al/Cu 1x 240 output 4x35/3x50mm² MOREK, MAB1401S10

€46,95

H50 solid front panel W400 QCC040501 SpEe ABB, 1SZE980010B0010
ABB
Blank COMBI panel 50 × 400 mm ABB 1SZE980010B0010
€19,39 €23,65
RCCB 4P 100A 100mA TX3 series ID type A Legrand, LEGRAND LOW VOLTAGE, 411778
RCD 4P 100A 100 mA series TX3 ID type A Legrand, LEGRAND LOW VOLTAGE, 411778
€128,99 €157,30
TeSys E contactor 3P 75kW (160A AC-3) 1NO-1NC 220V 50Hz SE, SCHNEIDER ELECTRIC LOW VOLTAGE, LC1E160M5
Easy TeSys three-pole contactor, 160 A AC-3, 220 V AC coil Schneider Electric LC1E160M5
€316,36 €385,80
DX3 3P 80A curve C 16kA 4.5 modules automatic circuit breaker, Legrand, LEGRAND LOW VOLTAGE, 408662
Circuit breaker DX3 3P 80A curve C 16kA 4,5 modules Legrand, LEGRAND LOW VOLTAGE, 408662
€170,56 €208,00
Contactor CTX3-400 3P 147kW (265A AC-3) 2NO-2NC 230V 50/60Hz Legrand, LEGRAND LOW VOLTAGE, 416306
Contactor CTX3-400 3P 147kW (265A AC-3) 2NO-2NC 230V 50/60Hz Legrand, LEGRAND LOW VOLTAGE, 416306
€607,62 €741,00
Contactor AF146-30-00B 3P 75kW (146A AC-3) 48...130V 50/60Hz ABB, 1SFL467002R1200
ABB
Busbar contactor AF146-30-00B-12, 75 kW AC-3 at 400 V AC, 48–130 V AC/DC ABB 1SFL467002R1200
€358,27 €436,91
Contactor AF96-30-11 3P 45kW (96A AC-3) 1NO+1NC 48...130V 50/60Hz ABB, 1SBL407001R1211
ABB
Contactor AF96-30-11 3P 45kW (96A AC-3) 1NO+1NC 48...130V 50/60Hz ABB, 1SBL407001R1211
€244,53 €298,21
Rotary switch 0-1 3P 32A IP65 red door handle SE, SCHNEIDER ELECTRIC LOW VOLTAGE, VCF1
Cam changeover switch 0-1 3P 32A IP65 red door handle SE, SCHNEIDER ELECTRIC LOW VOLTAGE, VCF1
€34,28 €41,81
RCCB 4P 63A 300mA series F204 type A ABB, 2CSF204101R3630
ABB
F204 A-63/0.3 residual current circuit breaker, 4P, 63 A, 300 mA, type A ABB 2CSF204101R3630
€148,04 €180,54
TeSys D contactor 4P 4NO (32A AC-1) 24Vdc SE, SCHNEIDER ELECTRIC LOW VOLTAGE, LC1DT32BD
TeSys Deca contactor, 4P 4 NO, 32 A AC-1, 24 V DC coil Schneider Electric LC1DT32BD
€101,40 €123,66
S753DR 3P 40A K-curve 25kA automatic circuit breaker ABB, 2CDH783010R0557
ABB
Circuit breaker S753DR 3P 40A curve K 25kA ABB, 2CDH783010R0557
€244,31 €297,94
TeSys U motor starter 1P 2.2kW (12A AC-3) with 3…12A thermal protection 24V DC SE, SCHNEIDER ELECTRIC LOW VOLTAGE, LUCC12BL
Advanced control unit TeSys Ultra, 3…12 A, 24 V DC Schneider Electric LUCC12BL
€70,20 €85,61
GREY tunnel terminal 1P 245A with 6 openings OTL95-3 3xAl/Cu 6-95mm² 1000V MOREK, MAA3095A10
Tunnel terminal GREY 1P 245A with openings: 6 OTL95-3 3xAl/Cu 6-95mm² 1000V MOREK, MAA3095A10

€28,97

Locking protective cap for Ø22mm heads Osmoz Legrand, LEGRAND LOW VOLTAGE, 24188
Lockable transparent cover for Osmoz pushbutton heads Legrand 24188
€17,06 €20,80
OHBS9/1 72mm direct-mount handle for 63…125A disconnectors АВВ, ABB, 1SCA108689R1001
ABB
OHBS9/1 lever handle, black, 72 mm, direct mounting ABB 1SCA108689R1001
€5,13 €6,26
XL3 400 metal panel 1200x575x175mm Legrand, LEGRAND LOW VOLTAGE, 20107
Metal enclosure XL3 400 1200x575x175mm Legrand, LEGRAND LOW VOLTAGE, 20107
€283,33 €345,52
TeSys DF fused disconnect switch 1P 32A 10X38 mm 1000V= SE, SCHNEIDER ELECTRIC LOW VOLTAGE, DF101PV
Single-pole fuse holder TeSys DF, 32 A, 1000 V DC Schneider Electric DF101PV
€6,36 €7,75
Time-delay relay for TeSys D, on-delay, 1x 0.1s…2s, 24...250Vac/dc SE, SCHNEIDER ELECTRIC LOW VOLTAGE, LA4DT0U
Time relay for TeSys D, on-delay, 1x 0.1s…2s, 24...250Vac/dc SE, SCHNEIDER ELECTRIC LOW VOLTAGE, LA4DT0U
€52,23 €63,70
Button head without button cap XB5 SE, SCHNEIDER ELECTRIC LOW VOLTAGE, ZB5AA0
Harmony XB5 non-illuminated pushbutton head Ø22 mm without cap Schneider Electric ZB5AA0
€3,97 €4,84
CR-M interface relay, 110 VAC, 12A, 2 changeover contacts, socket mounting ABB, 1SVR405611R7000
ABB
Plug-in relay CR-M110AC2, 110 V AC, 2 changeover contacts ABB 1SVR405611R7000
€6,46 €7,88
AF146-30-22 contactor, 3P 75kW (146A AC-3) 2NO+2NC 100...250V 50/60Hz ABB, 1SFL467001R1322
ABB
Three-pole contactor AF146-30-22-13, 75 kW, 100–250 V AC/DC ABB 1SFL467001R1322
€347,34 €423,58
Distribution terminal block СИВ 1P 80A OJL80A input Al/Cu 2x16 output 6x6mm² MOREK, MAB1080S10
Gray single-pole distribution terminal block OJL80A MOREK MAB1080S10

€14,91

CTX3-65 contactor 3P 22kW (50A AC-3) 2NO-2NC 24V DC Legrand, LEGRAND LOW VOLTAGE, 416141
Contactor CTX3-65 3P 22kW (50A AC-3) 2NO-2NC 24V DC Legrand, LEGRAND LOW VOLTAGE, 416141
€116,19 €141,70
Surface-mounted distribution board ComfortLine 1100x550x215 B27 with solid metal door IP44 ABB, 2CPX052069R9999
ABB
Surface-mounted distribution board ComfortLine 1100x550x215 B27 with solid metal door IP44 ABB, 2CPX052069R9999
€199,93 €243,82
Surface-mounted distribution board, 2x12 modules, Easy 9 EU, with solid white door and N and PE terminals, SE, SCHNEIDER ELECTRIC LOW VOLTAGE, EZ9EUD212
Surface-mounted distribution board, 2x12 modules, Easy 9 EU, with solid white door and N and PE terminals, SE, SCHNEIDER ELECTRIC LOW VOLTAGE, EZ9EUD212
€22,37 €27,28
Multifunction time relay, 10x 0.1s...10d, 1c/o 16A, 12...240Vac/dc, 1DIN, Elko EP, ELKO EP, CRM-91H/UNI
Multifunction time relay, 10x 0.1s...10d, 1c/o 16A, 12...240Vac/dc, 1DIN, Elko EP, ELKO EP, CRM-91H/UNI

€44,78

Popular

VGTECH

More from VGTECH

Latrans

More from Latrans

COMMEL

More from COMMEL

ORNO

More from ORNO

BTICINO

More from BTICINO

LEGRAND

More from LEGRAND

Recently viewed

Distribution boards and electrical equipment brings together enclosures, protective devices, controls and assembly components. Start with each part's task to compare the products required in the appropriate area.

Choose the enclosure and its contents separately

In electrical distribution boards , distinguish distribution enclosures from industrial and socket configurations. Check mounting, space and included contents. The box itself does not mean a complete wired distribution board. For mounting elements, terminals, busbar combs and supplementary enclosure parts, continue to distribution board assembly. Keep the enclosure, mechanical base and conductor connections as different items.

Distinguish protection areas

In circuit breakers and fuses , first choose between an automatic device, fuse link and load-break or disconnecting version. Then compare the exact series and parameters required. For other protection tasks, use residual current devices and surge protection. The general label “protection” does not make different equipment types equivalent substitutes.

In every area, separate the main device from spare parts and accessories. An interchangeable module, holder or additional contact should not be assumed to be a complete set. Keep the product's full designation and check its exact configuration, especially when some existing equipment remains in use.

Control, timed tasks and operator elements

Continue to motor control and protection for contactor, motor protection, thermal overload and variable frequency areas. For individual relay functions, explore relays and timers. Compare function, power supply version, outputs and mounting space by the specific reference. Control section data should not be confused with the parameters of the remaining equipment.

For the control panel, use push buttons, indicators and switches. Separate the assembled device from its head, contact and mounting elements. An empty control station and a complete offer are different purchases. Colour or similar shape alone does not determine package contents or compatibility between parts from different series. Note separately supplied markings and mounting parts.

For the final list, record every component's purpose, exact code, required accessories and included parts. For enclosures, check their own use conditions; for devices, compatibility with the specific equipment. This organises the actual solution by function without deriving general electrical characteristics or compatibility from membership of one category.