Air terminals

Мачта MAT3503 3м D35 за мълниеприемник с изпреварващо действие OPR ABB, 2CTH070011R0000
ABB
Mast MAT3503, 3 m, D35, for early streamer emission lightning terminal OPR ABB, 2CTH070011R0000
€426,90 €520,61
Брояч на мълнии ABB, 2CTH0CCF2004
ABB
Lightning strike counter ABB, 2CTH0CCF2004
€658,87 €803,50
Мачта MAT3002 2.3м D30 за мълниеприемник с изпреварващо действие OPR ABB, 2CTH070002R0000
ABB
Mast MAT3002 2.3m D30 for early streamer emission lightning rod OPR ABB, 2CTH070002R0000
€181,70 €221,58
Свързващ комплект KFP0035 към мачта MAT3503 3м ABB, 2CTH050027R0000
ABB
KFP0035 connection kit for MAT3503 mast, 3 m, ABB, 2CTH050027R0000
€62,03 €75,65
Бетонна основа 18.6кг за мълниеприемен прът до Ø23мм Elemko, ЗАЗЕМЛЕНИЕ И МЪЛНИЕЗАЩИТА, 6130300
Concrete base 18.6 kg for air-termination rod up to Ø23mm, Elemko, EARTHING AND LIGHTNING PROTECTION, 6130300

€39,70

Удължител RAL4202 2м към мачта D42 ABB, 2CTH070007R0000
ABB
Extension RAL4202 2m for mast D42 ABB, 2CTH070007R0000
€433,16 €528,24
Удължител RAL3502 2м към мачта D35 ABB, 2CTH070005R0000
ABB
Extension RAL3502 2m for mast D35 ABB, 2CTH070005R0000
€266,86 €325,44
Мълниеприемник HPI3002 2м от неръждаема стомана ABB, 2CTH010002R0000
ABB
Air terminal HPI3002 2m, stainless steel ABB, 2CTH010002R0000
€179,66 €219,10
Мълниеприемен прът алуминиев Ø15х2000мм Elemko, ЗАЗЕМЛЕНИЕ И МЪЛНИЕЗАЩИТА, 6440520-71
Aluminium air-termination rod Ø15х2000mm Elemko, EARTHING AND LIGHTNING PROTECTION, 6440520-71

€21,78

Мълниеприемен прът алуминиев Ø15х2500мм Elemko, ЗАЗЕМЛЕНИЕ И МЪЛНИЕЗАЩИТА, 6440525-71
Aluminium air termination rod Ø15х2500mm Elemko, EARTHING AND LIGHTNING PROTECTION, 6440525-71

€26,95

Мачта RAL4203 3м D42 за мълниеприемник с изпреварващо действие OPR ABB, 2CTH070008R0000
ABB
Mast RAL4203 3 m D42 for early streamer emission air terminal OPR ABB, 2CTH070008R0000
€554,01 €675,62
Мълниеприемен прът алуминиев Ø15х3000мм Elemko, ЗАЗЕМЛЕНИЕ И МЪЛНИЕЗАЩИТА, 6440530-71
Aluminium air-termination rod Ø15х3000mm, Elemko, EARTHING AND LIGHTNING PROTECTION, 6440530-71

€31,76

Мълниеприемник с изпреварващо действие OPR, 30ms, ABB, 2CTB899800R7000
ABB
Early streamer emission air terminal OPR, 30ms, ABB, 2CTB899800R7000
€970,07 €1.183,01
Мълниеприемник с изпреварващо действие OPR, 45ms, ABB, 2CTB899800R7500
ABB
Early streamer emission air terminal OPR, 45ms, ABB, 2CTB899800R7500
€1.115,05 €1.359,82
Мълниеприемник с изпреварващо действие OPR, 60ms, ABB, 2CTB899800R7100
ABB
Early streamer emission air terminal OPR, 60ms, ABB, 2CTB899800R7100
€1.524,22 €1.858,80

Recently viewed

Choosing an air termination begins with the project and specific component's role. This group includes rods, masts, extensions and bases that must be coordinated as separate parts.

Distinguish the rod from the support structure

The ELEMKO 6440520 aluminium air termination rod is a separate element for which the manufacturer specifies an independently selected base, fixings and connection clamp. These accessories are not included with the rod. When preparing the order list, check every item instead of assuming that one product is a complete installation kit.

Related rods of different lengths have separate geometric data and accessory references. Choose the exact model for the design height and intended mounting. A longer rod alone does not justify promising a particular protected area. Consider the mast and extension according to their own intended uses as well. Check every transition between the rod, support and fasteners.

The base has a specific mechanical interface

The 6130300 concrete base is a support component. It is not an air terminal or a complete lightning protection system. For combination with a rod, request confirmation of the exact interface, fixing and applicable accessories. A similar diameter description or general name “base” does not replace checking the specific combination.

Prepare assembly according to the design

Specify the mounting surface type, intended rod position and structural constraints. The designer must determine the required height, stability and fixing for the site. Do not choose solely by appearance or an early streamer emission designation: this is insufficient to determine a protection radius independently.

Separate mechanical parts from electrical connection. For the route, explore earthing bars and conductors; for connections between components, explore earthing connection terminals. These categories help with assembly, but specific cross-sections, materials and combinations must remain aligned with the design.

Order verifiable individual items

In earthing and lightning protection , organise the entire list by function. For every item, record the full model, quantity and accessories required. For replacement, add existing parts' designations. Before ordering, clarify what the package actually includes and what is selected separately to avoid a missing base, fixing or connection during installation.