Electrical supplies

Solid mounting plate H1000 W600 QM0610000 SpEe ABB, 1SZE980070B0110
ABB
Mounting plate H1000 solid W600 QM0610000 SpEe ABB, 1SZE980070B0110
€96,99 €118,28
Cable 2x2x0.5+S LSZH Cca red – 100m PH120 ELAN, CABLES, 284051R
Cable 2x2х0.5+S LSZH Cca red – 100m PH120 ELAN, CABLES, 284051R

€161,52

Drywall mounting box Ф85 depth 60mm Batibox Legrand, LEGRAND, 80086L
Drywall mounting box Ф85, depth 60 mm, Batibox Legrand, LEGRAND, 80086L
€4,17 €5,08
2+2-module metal frame, Pure White AIR LL Bticino, BTICINO, LNE4802M2BN
Metal frame 2+2 modules, Pure white AIR LL Bticino, BTICINO, LNE4802M2BN
€24,34 €33,80
Holder for 7 black Duplix Legrand markers, LEGRAND, 38450
Holder for 7 markers, black Duplix Legrand, LEGRAND, 38450
€0,22 €0,27
French-standard socket, 16A, surface-mounted, IP66, with load connected, Protecta series, 95x95mm, Scame-137.6411
FRENCH-standard socket 16A for surface mounting IP66 with a load plugged in, Protecta series 95х95 mm, Scame-137.6411
€15,93 €19,43
RJ45 STP cat.6A socket S-One, Anthracite color, Sedna SE, SCHNEIDER ELECTRIC, SDD114466S
Socket RJ45 STP cat.6A S-One anthracite Sedna SE, SCHNEIDER ELECTRIC, SDD114466S
€17,03 €20,77
LIYCY cable 5 x 0.75 gray, CABLES, 01102125
Cable LIYCY 5 x 0.75 grey, CABLES, 01102125

€1,85

Desk module, 1x Schuko and 2x USB Type A+C, 2 m cable, Anthracite / Fabric Unica System+ SE, SCHNEIDER ELECTRIC, INS44051
Desk module with 1х Schuko socket and 2хUSB Type A+C, 2 m cable, Anthracite / Textile finish Unica System+ SE, SCHNEIDER ELECTRIC, INS44051
€91,95 €112,13
Contactor AF190-30-22 3P 90kW (190A AC-3) 2NO+2NC 250...500V 50/60Hz ABB, 1SFL487002R1422
ABB
Contactor AF190-30-22 3P 90kW (190A AC-3) 2NO+2NC 250...500V 50/60Hz ABB, 1SFL487002R1422
€434,10 €529,39
KAPSA cover XS, Black, Bachmann, BACHMANN, B927.301
Cover KAPSA XS, matte black, 151 x 5 x 70 mm BACHMANN 927.301
€47,63 €58,08
CABLE PVV-MB1 3X1.50 220/380V 50M ROLL - LTR01010046
CABLE ПВВ-МБ1 3Х1.50 220/380V 50М ROLL - LTR01010046

€40,68

BD2 Al 800A busbar trunking IP55, 3.25 m long, with 6+6 outlets Siemens, SIEMENS, BD2A-3-800-SB-3
Busbar trunking BD2 Al 800A IP55 length 3.25m with outlets: 6+6 Siemens, SIEMENS, BD2A-3-800-SB-3

€1.820,31

Touch-sensitive Lightcube wall lamp, warm white, Allocacoc, 10202/EUOWLC
Lightcube touch-sensitive warm white wall light, Allocacoc, 10202/EUOWLC
€10,77 €11,97
Two-way switch mechanism with indicator, Anthracite, IP55, Plexo New Legrand, LEGRAND, 69802L
Two-way switch mechanism with indicator, anthracite colour IP55 Plexo New Legrand, LEGRAND, 69802L
€11,23 €15,60
Frame 3-gang 55x55 Deep FF/Linea71/20Venti Fenix Grey London EKINEX, EK-D3P-FGL
Frame 3х 55x55 Deep FF/Linea71/20Venti Fenix Grey London EKINEX, EK-D3P-FGL

€244,32

Perforated cable tray 200x60mm Niedax, CABLE TRAYS, RLVC 60.200
Perforated cable tray 200х60mm Niedax, CABLE TRAYS, RLVC 60.200

€10,45

Metal enclosure 1400×400×250 Q843B414 SpEe L IP43 ABB, 1SZE430800B0050
ABB
Metal enclosure 1400×400×250 Q843B414 SpEe L IP43 ABB, 1SZE430800B0050
€234,91 €286,48
ALKALINE BATTERIES ENR MAX ALK C CHP2 ENERGIZER
ALKALINE BATTERIES ENR MAX ALK C CHP2 ENERGIZER

€5,57

Contactor AF370-30-22 3P 200kW (370A AC-3) 2NO+2NC 24...60V 50/60Hz ABB, 1SFL607002R1122
ABB
Contactor AF370-30-22 3P 200kW (370A AC-3) 2NO+2NC 24...60V 50/60Hz ABB, 1SFL607002R1122
€897,85 €1.094,94
Fourth pole OTPS40FDN1 for 16…40A ABB switch disconnector, 1SCA104999R1001
ABB
Fourth pole OTPS40FDN1 for side mounting, ABB 1SCA104999R1001
€6,34 €7,73
Busbar trunking connector BD2 160…400A IP55 Siemens, SIEMENS, BD2-400-EK
Connector for busbar trunking BD2 160…400A IP55 Siemens, SIEMENS, BD2-400-EK

€213,69

Cover for Ø85 junction box Legrand, LEGRAND, 80180
Box cover Ф85 Legrand, LEGRAND, 80180
€1,71 €2,08
Solid door 1600×800 Q855D800 SpEe M IP55 ABB, 1SZE990910B0220
ABB
Solid door 1600×800 Q855D800 SpEe M IP55 ABB, 1SZE990910B0220
€188,30 €229,64
Trapezoidal hanger for M10 threaded rod Niedax, CABLE TRAYS, DBT 40
Trapezoidal hanger for М10 threaded rod Niedax, CABLE TRAYS, DBT 40

€1,27

Automatic fire extinguishing device for spaces up to 15m³ EGO Blast 150 MAUS, 4003-150
Automatic fire suppression device for volumes up to 15m³, EGO Blast 150 MAUS, 4003-150

€2.396,40

Multi-standard socket outlet 2P+E 13A 2 modules, cream gloss, Modul TEM, VM55IW
TEM
Multi-standard socket 2P+E 13A 2 modules, Gloss Cream, Modul TEM, VM55IW
€12,20 €14,88
TeSys D contactor, 3P, 5.5kW (12A AC-3), 1NO-1NC, 24V 50/60Hz SE, SCHNEIDER ELECTRIC LOW VOLTAGE, LC1D12B7
Contactor TeSys D 3P 5.5kW (12A AC-3) 1NO-1NC 24V 50/60Hz SE, SCHNEIDER ELECTRIC LOW VOLTAGE, LC1D12B7
€39,50 €48,17
Supply terminal S1-M3-35 for MS116/132 ABB, 1SAM201913R1103
ABB
Supply terminal S1-M3-35 for MS116/132 ABB, 1SAM201913R1103
€19,91 €24,28
2-module 55x55 Surface Linea71/20Venti Fenix Grey Ephesus EKINEX, EK-S2P-FGE
Frame 2х 55x55 Surface Linea71/20Venti Fenix Grey Ephesus EKINEX, EK-S2P-FGE

€116,40

Recently viewed

Electrical supplies are chosen as parts of a specific solution: a new socket beside the desk, replacement switches in a room, a planned cable route or equipping a distribution board. The visible detail is often only the start of the list. At Latrand, these tasks bring together switches and outlets, electrical equipment, cables, installation materials, power supplies and measuring equipment. A useful starting point is what already exists at the location and exactly what needs to be added or replaced.

Switches and sockets: faceplate, mechanism and location

When refreshing an interior, colour matters, but first establish the range and the components that make up the product. Under frames, faceplates and mechanisms, these elements form a separate group. A picture does not always reveal whether an offer is a complete set or just one component. Note the functions needed, the number of positions and their arrangement; then compare the stated contents of each chosen item.

A workspace may combine mains power, a network connection and device charging. Explore sockets and outlets by their intended use instead of gathering mechanisms that look alike. When the furniture layout changes, furniture sockets and floor boxes raise other questions: where there is room for the housing, how it can be reached and where the cables will run. The opening dimensions and clear space matter just as much as the visible surface.

When the power point needs to move

When equipping a desk or temporary workspace, explore power strips and extension leads. Note the length needed, the number of planned devices and where the product will sit. Pay attention to the spacing between outlets if plugs or adapters are bulky. A switch, an additional port and the stated protective features are separate characteristics; the presence of one does not imply the others.

For a switch that controls a particular appliance, keep the required function on the list. A dimmer, a water heater switch and a conventional light switch should not be chosen on colour alone. Note the intended use and exact range so you compare suitable versions within the relevant group.

Plan the distribution board from the inside out

The enclosure and the equipment play different roles in the purchase. For electrical enclosures, compare the mounting method, dimensions and stated capacity against the prepared project. An equipped product and an empty enclosure do not contain the same things. Doors, cable entry points and included mounting parts also deserve a check before choosing a particular model.

The enclosures and electrical equipment section has separate groups for circuit breakers, fuses, residual current devices, surge protection, relays and motor control. These are different product groups whose purposes cannot be inferred from similar housings. Selecting protective devices and their specifications is a specialist's task according to the installation. For the purchase, prepare the exact designations from that specialist's list and list the assembly accessories separately so they are not lost among the main devices.

Follow the cable route step by step

When a cable needs to reach one point from another, look at the entire route. Are there bends, transitions between rooms, sections behind furniture or areas with limited access? Cable routing and installation materials include conduits, trunking, trays, boxes and fixings. Choosing between them starts with the planned method and conditions at the location, while the specific dimensions follow the route required.

For cable trunking and accessories, count not only the straight sections but also the places that need the corresponding transition or end pieces. For a conduit system, examine the available accessories for the chosen range separately. Mounting and junction boxes are compared according to the mounting surface, shape and space for the intended application. This allows the list to reflect the actual location rather than contain only the main material.

For a room with finished floors and furniture, mark the reference points on a simple sketch. Show the starting and finishing points, box positions and visible sections. This helps you compare the external dimensions of the chosen products and separate decorative preferences from the limits of the space.

Cable, connection and identification are separate choices

The cables and connections category includes power conductors, signal and control cables, ferrules, cable joints, terminals and cable glands. The name of the general group is not enough to justify replacing one item with another. For a specified cable, retain its full designation; for a connector or ferrule, compare the exact types and sizes it is intended for.

Prepare separate lines for terminals and quick connectors and the installation accessories needed. Also establish the unit of sale and package contents: a length, a single piece and a set are not interchangeable quantities. For several cables, consider cable identification when preparing the shopping list. The type of marking, where it will be read and its suitability for the chosen identification system all matter.

Power starts with the device's requirements

For a power supply unit, prepare the details of the device to be powered and the intended location of the unit. Compare the stated input and output specifications, output type, dimensions and mounting method. For an LED power supply or driver, follow the requirements of the particular lighting; the same general application does not establish compatibility between arbitrary models.

For batteries and rechargeable batteries, start with the designation in the appliance or its manual. Shape alone is not enough to make a choice. If considering a charger, check which batteries it explicitly supports. For a UPS or portable power station, describe which devices you intend to use and their requirements before comparing individual offers.

Measurement and specialist systems

Electricity meters and energy meters are part of the electrical supplies selection. Establish what the device needs to measure, where it will be installed and how you will read its measurements. Compare only functions stated for the particular model. A similar appearance does not indicate its connection method or suitability for the planned installation.

Charging stations and solar components, along with earthing and lightning protection, require a separate technical specification. Gather the project designations and accessory list rather than adding them by analogy with an ordinary socket. Before ordering, review each item by model, quantity, completeness and role in the project. A clear list allows a missing detail to be identified without changing the technical solution.

When renovating several rooms, group the items by room and combine identical products by their exact code. This keeps different colours, frames or versions from becoming mixed in the total quantity. Leave a note beside each unconfirmed item so it can be clarified before the final choice.