Electrical supplies

Yellow latching mechanism for Ø22mm XB4 SE pushbutton, SCHNEIDER ELECTRIC LOW VOLTAGE, ZB4BZ65
Yellow locking mechanism for Ø22mm push-button XB4 SE, SCHNEIDER ELECTRIC LOW VOLTAGE, ZB4BZ65
€14,10 €17,20
Furniture box with 5 Schuko sockets and USB type A+C, 2m cable, 393x171mm, METAL color, Incara Flip-Up Legrand, LEGRAND, 654856
Furniture box with 5х Schuko sockets and USB type A+C, 2m cable, 393x171mm, METAL colour, Incara Flip-Up Legrand, LEGRAND, 654856
€359,59 €438,53
Adapter for Mosaic 45x45 mm with transparent cover, mechanism, White, IP55, Plexo New Legrand, LEGRAND, 69695L
Adapter for Mosaic 45x45 mm mechanism with transparent cover, white, IP55 Plexo New Legrand, LEGRAND, 69695L
€10,30 €14,30
Speaker socket, 1 module, white, Light Now Bticino, BTICINO, YW4294
Speaker socket, 1 module, white, Light Now Bticino, BTICINO, YW4294
€22,39 €27,30
Illuminated button with "lamp" symbol, Anthracite color, Sedna SE, SCHNEIDER ELECTRIC, SDD114132L
Illuminated push-button with "lamp" symbol, Anthracite, Sedna SE, SCHNEIDER ELECTRIC, SDD114132L
€12,36 €15,07
ATRA - Two-way switch 10A surface-mounted IP21 white - 5126, АТРА
ATRA - Two-way switch 10A for surface mounting, IP21, white - 5126, АТРА
€6,71 €7,89
NSX160N 3P circuit breaker without protection 50kA SE, SCHNEIDER ELECTRIC LOW VOLTAGE, C16N3
Circuit breaker NSX160N 3P without protection 50kA SE, SCHNEIDER ELECTRIC LOW VOLTAGE, C16N3
€381,85 €465,67
Surface-mount box IP55 3 modules color Gloss White Modul TEM, AQ30PW
TEM
Surface mounting box IP55 3 mod., glossy white, Modul TEM, AQ30PW
€8,27 €10,08
Push button with "bell" symbol, IP44, White, Sedna SE, SCHNEIDER ELECTRIC, SDD211131
Push-button with "bell" symbol IP44, white, Sedna SE, SCHNEIDER ELECTRIC, SDD211131
€6,09 €7,43
10-meter extension cord, AT N07V3V3-F 5G2.5mm2, yellow, IP44, Commel, COMMEL, C221-102
Extension lead, 10 metres, AT N07V3V3-F 5G2.5мм2 cable, yellow, IP44 Commel, COMMEL, C221-102
€62,54 €76,27
Energy-saving device with RFID card reader, 3 modules, matte cream color Modul TEM, EM46MI
TEM
Energy saver with RFID card reader, 3 modules, Matt Cream, Modul TEM, EM46MI
€72,01 €87,82
2xUSB charging socket, type A+A, 2.1A, 10.5W, 2 modules, cream color Unica SE, SCHNEIDER ELECTRIC, NU341844
2хUSB type A+A charging socket, 2.1A 10.5W, 2 modules, cream, Unica SE, SCHNEIDER ELECTRIC, NU341844
€44,12 €53,81
S753DR 3P 63A curve K 25kA automatic circuit breaker ABB, 2CDH783010R0607
ABB
Circuit breaker S753DR 3P 63A curve K 25kA ABB, 2CDH783010R0607
€244,52 €298,19
PrismaSet XS flush-mounted distribution board, 120 modules (5x24), mod. with white solid door and N and PE terminals, SE, SCHNEIDER ELECTRIC LOW VOLTAGE, LVSXN524
PrismaSet flush-mounted enclosure XS 120 modules (5х24) mod., with white opaque door and Н and РЕ terminals SE, SCHNEIDER ELECTRIC LOW VOLTAGE, LVSXN524
€430,50 €525,00
Rigid pipe outer diameter 32 mm, inner diameter 25.7 mm, 750N, class 3343, black, UV-stabilized, HF, DUROSOL, 3 m /30 m/ Kouvidis, KOUVIDIS, KD1030032
Rigid conduit, outer Ø32 mm inner Ø25.7 mm 750N class 3343, black, UV-stabilised HF DUROSOL 3 m /30 m/ Kouvidis, KOUVIDIS, KD1030032

€1,92

NSX250DC PV Circuit Breaker 4P 200A 10kA 1000V= adjustable (In x 0.7...1) SE, SCHNEIDER ELECTRIC LOW VOLTAGE, C25F4TM200D1
Circuit breaker NSX250DC PV 4P 200A 10kA 1000V= adjustable (In x 0.7...1) SE, SCHNEIDER ELECTRIC LOW VOLTAGE, C25F4TM200D1
€543,96 €663,37
Insulated terminal GREEN 11x16mm²+15x6mm² 100A АВВ, ABB, 1SPE007715F0745
ABB
GREEN insulated terminal 11x16mm²+15x6mm² 100A АВВ, ABB, 1SPE007715F0745
€6,60 €8,05
Solid metal mounting plate 270x270mm Thalassa PLS SE, SCHNEIDER ELECTRIC LOW VOLTAGE, NSYPMM2727
Solid metal mounting plate 270x270 mm Thalassa PLS SE, SCHNEIDER ELECTRIC LOW VOLTAGE, NSYPMM2727
€11,76 €14,34
H450 module for 1x MCCB XT5 vertical W600 QB5V64500 SpEe ABB, 1SZE980040B0130
ABB
Module H450 for 1х MCCB XT5 vertical W600 QB5V64500 SpEe ABB, 1SZE980040B0130
€83,92 €102,34
Flip-S 4M module with 2x Schuko sockets, USB Type A+C and 1x blank module, color Gray/Aluminum, ABL, ABL Serbia, 2G42F2A4
Module Flip-S 4M with 2х Schuko, USB type A+C and 1х blank module, grey/aluminium, ABL, ABL Serbia, 2G42F2A4

€130,80

Latrand
Monolithic yellow LED indicator light 220...230Vac Ø22mm IP66 Compact Scame, SCAME, 590.PLM052
€5,71 €6,96
Type 1+2 surge arrester Acti 9 iPRD1 12.5kA 350V 3P with indicator SE, SCHNEIDER ELECTRIC LOW VOLTAGE, A9L16382
Surge arrester type 1+2 Acti 9 iPRD1 12.5kA 350V 3P with indication SE, SCHNEIDER ELECTRIC LOW VOLTAGE, A9L16382
€255,02 €311,00
BD01 busbar trunking 160A IP54 length 2m 2 outlets Siemens, SIEMENS, BD01-160-2-1
Busbar trunking BD01 160A IP54 length 2m 2 outlets Siemens, SIEMENS, BD01-160-2-1

€290,77

PIR motion sensor, 110° range, 8m @ h=1.2 mod. 5A, requires neutral, 1 module, matte white color, Modul TEM, EM31MW
TEM
PIR motion sensor 110°, range 8m @ h=1.2 modules, 5A, neutral required, 1 module, matt white, Modul TEM, EM31MW
€92,09 €112,30
TeSys D contactor 3P 80kW (150A AC-3) 1NO+1NC 48...130Vac/dc Everlink SE, SCHNEIDER ELECTRIC LOW VOLTAGE, LC1D150AEHE
Contactor TeSys D 3P 80kW (150A AC-3) 1NO+1NC 48...130Vac/dc Everlink SE, SCHNEIDER ELECTRIC LOW VOLTAGE, LC1D150AEHE
€426,92 €520,64
Surface-mounted ComfortLine distribution board, 4x12 modules, CA14V, with solid metal door, IP44, and N and PE terminals ABB, 2CPX052181R9999
ABB
Surface-mounted distribution board ComfortLine CA14V, 4×12 modules, IP44 ABB 2CPX052181R9999
€167,28 €204,00
3-phase variable speed drive 1.5kW ATV320 book 380...500V IP21 SE, SCHNEIDER ELECTRIC LOW VOLTAGE, ATV320U15N4B
Variable frequency drive 3P 1.5kW ATV320 book 380...500V IP21 SE, SCHNEIDER ELECTRIC LOW VOLTAGE, ATV320U15N4B
€601,26 €733,24
Rotary dimmer R=0-180W LED=0-180VA 1 module, matte black Modul TEM, EM14SB
TEM
Rotary dimmer R=0-180W LED=0-180VA 1 modules matt black Modul TEM, EM14SB
€95,64 €116,64
10A SWISS standard socket outlet for surface mounting, IP66, with load switched on, Protecta series, 95x95 mm, Scame-137.6417
SWISS-standard socket 10 A, surface-mounted, IP66 with a load connected, Protecta series, 95х95 mm, Scame-137.6417
€13,00 €15,85
Push button with bell symbol, Anthracite color, Sedna SE, SCHNEIDER ELECTRIC, SDD114131
Push-button with “bell” symbol, anthracite, Sedna SE, SCHNEIDER ELECTRIC, SDD114131
€6,16 €7,51

Recently viewed

Electrical supplies are chosen as parts of a specific solution: a new socket beside the desk, replacement switches in a room, a planned cable route or equipping a distribution board. The visible detail is often only the start of the list. At Latrand, these tasks bring together switches and outlets, electrical equipment, cables, installation materials, power supplies and measuring equipment. A useful starting point is what already exists at the location and exactly what needs to be added or replaced.

Switches and sockets: faceplate, mechanism and location

When refreshing an interior, colour matters, but first establish the range and the components that make up the product. Under frames, faceplates and mechanisms, these elements form a separate group. A picture does not always reveal whether an offer is a complete set or just one component. Note the functions needed, the number of positions and their arrangement; then compare the stated contents of each chosen item.

A workspace may combine mains power, a network connection and device charging. Explore sockets and outlets by their intended use instead of gathering mechanisms that look alike. When the furniture layout changes, furniture sockets and floor boxes raise other questions: where there is room for the housing, how it can be reached and where the cables will run. The opening dimensions and clear space matter just as much as the visible surface.

When the power point needs to move

When equipping a desk or temporary workspace, explore power strips and extension leads. Note the length needed, the number of planned devices and where the product will sit. Pay attention to the spacing between outlets if plugs or adapters are bulky. A switch, an additional port and the stated protective features are separate characteristics; the presence of one does not imply the others.

For a switch that controls a particular appliance, keep the required function on the list. A dimmer, a water heater switch and a conventional light switch should not be chosen on colour alone. Note the intended use and exact range so you compare suitable versions within the relevant group.

Plan the distribution board from the inside out

The enclosure and the equipment play different roles in the purchase. For electrical enclosures, compare the mounting method, dimensions and stated capacity against the prepared project. An equipped product and an empty enclosure do not contain the same things. Doors, cable entry points and included mounting parts also deserve a check before choosing a particular model.

The enclosures and electrical equipment section has separate groups for circuit breakers, fuses, residual current devices, surge protection, relays and motor control. These are different product groups whose purposes cannot be inferred from similar housings. Selecting protective devices and their specifications is a specialist's task according to the installation. For the purchase, prepare the exact designations from that specialist's list and list the assembly accessories separately so they are not lost among the main devices.

Follow the cable route step by step

When a cable needs to reach one point from another, look at the entire route. Are there bends, transitions between rooms, sections behind furniture or areas with limited access? Cable routing and installation materials include conduits, trunking, trays, boxes and fixings. Choosing between them starts with the planned method and conditions at the location, while the specific dimensions follow the route required.

For cable trunking and accessories, count not only the straight sections but also the places that need the corresponding transition or end pieces. For a conduit system, examine the available accessories for the chosen range separately. Mounting and junction boxes are compared according to the mounting surface, shape and space for the intended application. This allows the list to reflect the actual location rather than contain only the main material.

For a room with finished floors and furniture, mark the reference points on a simple sketch. Show the starting and finishing points, box positions and visible sections. This helps you compare the external dimensions of the chosen products and separate decorative preferences from the limits of the space.

Cable, connection and identification are separate choices

The cables and connections category includes power conductors, signal and control cables, ferrules, cable joints, terminals and cable glands. The name of the general group is not enough to justify replacing one item with another. For a specified cable, retain its full designation; for a connector or ferrule, compare the exact types and sizes it is intended for.

Prepare separate lines for terminals and quick connectors and the installation accessories needed. Also establish the unit of sale and package contents: a length, a single piece and a set are not interchangeable quantities. For several cables, consider cable identification when preparing the shopping list. The type of marking, where it will be read and its suitability for the chosen identification system all matter.

Power starts with the device's requirements

For a power supply unit, prepare the details of the device to be powered and the intended location of the unit. Compare the stated input and output specifications, output type, dimensions and mounting method. For an LED power supply or driver, follow the requirements of the particular lighting; the same general application does not establish compatibility between arbitrary models.

For batteries and rechargeable batteries, start with the designation in the appliance or its manual. Shape alone is not enough to make a choice. If considering a charger, check which batteries it explicitly supports. For a UPS or portable power station, describe which devices you intend to use and their requirements before comparing individual offers.

Measurement and specialist systems

Electricity meters and energy meters are part of the electrical supplies selection. Establish what the device needs to measure, where it will be installed and how you will read its measurements. Compare only functions stated for the particular model. A similar appearance does not indicate its connection method or suitability for the planned installation.

Charging stations and solar components, along with earthing and lightning protection, require a separate technical specification. Gather the project designations and accessory list rather than adding them by analogy with an ordinary socket. Before ordering, review each item by model, quantity, completeness and role in the project. A clear list allows a missing detail to be identified without changing the technical solution.

When renovating several rooms, group the items by room and combine identical products by their exact code. This keeps different colours, frames or versions from becoming mixed in the total quantity. Leave a note beside each unconfirmed item so it can be clarified before the final choice.